Table 1.
Summary of main problems and corresponding solutions for the digital endoscopic endonasal transsphenoidal pituitary surgery model
| Problem | Cause | Solution | 3D manipulation tools | Tools |
|---|---|---|---|---|
| File format transformation | DICOM file cannot be edited directly | Upload the DICOM file and save it as STL file | Mimics (17.0) | File New Project Wizard File Export ASCII STL Files |
| Non-skull parts | The result of CT scanning includes all compositions of the head | Set the thresholding value Select the parts in 3D and delete them | Menu bar Segmentation Thresholding Menu bar Segmentation Edit Mask in 3D Lasso Remove | |
| Missing structure | The limited accuracy of CT scanning and automatic threshold segmentation | Paint the parts slice by slice | Menu bar Segmentation Edit Masks Circle Draw | |
| The surgical area should be printed by the breakable and low-cost material (plaster) | The sellar region will be broken during the surgery | Segment the skull | 3ds Max (2014) | Slice Remove the top/Remove the bottom |
| Make internal carotid arteries, optic nerves and corresponding molds | The soft tissues should be protected carefully during the real surgery | Draw the objects and use Boolean operation | Compound Objects Boolean | |
| Wrong positions of holes | The limitation of CT scanning and automatic threshold segmentation | Fill the holes | Geomagic Studio (13.0) | Fill Holes Fill All |
| Inappropriate distribution of grids | The limitation of CT scanning | Analyze and optimize | Polygons Repair Remesh Polygons Smooth Relax Polygons Repair Decimate |