Skip to main content
. 2020 Jun 27;17(13):4624. doi: 10.3390/ijerph17134624

Table 2.

Infrared thermal measurements of the perioral region surface at the baseline during the mask wearing and after the device removal (mean, SD. Student’s t-test).

Temperature Baseline Temperature Inhalation Temperature Exhalation Temperature Mask Removal
Groups N95 Surgical Mask N95 Surgical Mask N95 Surgical Mask N95 Surgical Mask
Average (SD) 35.0 ± 2.8 °C 35.2 ± 3.1 °C 26.0 ± 3.6 °C 28.9 ± 3.1 °C 29.3° C ± 3.8 31.4° C ± 3.6 36.9 ± 4.2 °C 35.9 ± 3.4 °C
p-value p > 0.05 p < 0.01 p < 0.01 p < 0.01