List of measurement equipment used for measuring meteorology and physiology.

Measurements Equipment Model
(Name of the Manufacturer)
Accuracy Resolution Interval Note
Working environment
Air temperature AD-5696(A&D Co., Ltd.) ±1 °C 0.1 °C 10 min. Thermister
Relative humidity ±5% Rh 0.1% Rh 10 min. Capacitance
WBGT -- 0.1 °C 10 min. --
Physical workload
ECG(Smart clothing) COCOMI *1
(TOYOBO Co., Ltd.)
1 Ω/sq*2 0.3 mm *3 -- Stretchable conductive film
Heart rate sensor WHS-2 *4
(Union Tool Co., Ltd.)
-- 1 kHz *5 Per beat Analysis of R-R interval
3-axis acceleration -- 31.25 Hz *5 Per beat Capacitive sense
Infrastructure
Data acquisition time CC2650 *6 and ThinkPad
(Texas Instruments and Lenovo co., Ltd.)
-- 1 ms Per beat Synchronized time with server
Data transfer Raspberry Pi Zero W
(Raspberry Pi Foundation)
-- -- -- IEEE802.11 b/g/n
(Wireless LAN)
Bluetooth 4.1

Note: *1 Figure 1b; *2 sheet resistance of smart clothing; *3 Approximate thickness; *4 Figure 1a; *5 sampling in frequency; *6 Figure 1c.