Skip to main content
. 2020 Jul 6;5(28):17431–17441. doi: 10.1021/acsomega.0c01858

Table 4. Temperature Data of the Power Battery System with Different Inlet Flow Temperatures.

inlet flow temp (°C) max temp rise max temp difference max temp average difference
15 34.20 4.47 2.47
25 41.06 7.74 2.98
30 44.57 10.97 3.91