Table 4.

Shinyei PM sensor calibrations generated from first half of Hyderabad data and their accuracy when applied during a second later period where (Estimate PM) = m × (raw sensor signal) + b for all sensors except the PPD60PV where a nonlinear calibration was used.

Signal output Calibration coefficients (PM = m × sensor + b) calibration period application period

m b Dates average standard deviation dates average error standard deviation error
PPD42NSa Digital 40.0 13.3 (1/31–2/4) 0 28.9 (2/7–2/10) –149 145.3
PPD20V1 Analog 0.45 –75.5 (1/31–2/4, 2/7–2/10) 0 20.3 (2/25–3/4) 9.2 19.9
PPD20V2 Analog 0.46 –84.8 (1/31–2/4, 2/7–2/10) 0 21.6 (2/25–3/4) –15.9 16.3
PPD20V3 Analog 0.39 –50.4 (1/31–2/4, 2/7–2/10) 0 18.7 (2/25–3/4) –0.8 17

PM = esensordc Calibration period Application period

c d dates average standard deviation dates average error standard deviation error
PPD60PV Analog 123 2.8 (1/31–2/4, 2/7–2/10) 0 24.1 (2/25–3/4) –21.9 38.5