Skip to main content
. 2020 Jul 23;10:12263. doi: 10.1038/s41598-020-67844-3

Table 2.

Endpoint dose response for cAMP generation and arrestin recruitment stimulated by vasopressin and oxytocin via the V2 vasopressin receptor.

Ligand cAMP Arrestin
Emax NFU Emax % vaso − log L50 (L50, nM) Emax NFU Emax % vaso − log L50 (L50, nM)
Vasopressin 0.51 ± 0.09a 100 ± 0 10.05 ± 0.08b (0.089) 0.16 ± 0.02c 100 ± 0 7.68 ± 0.04d (21)
Oxytocin 0.56 ± 0.12a 110 ± 5 9.44 ± 0.13b (0.36) 0.16 ± 0.03c 97 ± 4 6.75 ± 0.08d (180)

The responses at a single time point (18 min after ligand application, 22 min after experiment initiation) were measured using genetically-encoded biosensors26,82 as described in Methods. See Fig. 6 for raw data. The data were fit to a sigmoid curve equation83 to determine the maximal initial rate (IRmax, the upper plateau, equivalent to kτ) and L50 (concentration of ligand giving an initial rate 50% of IRmax). Data values are mean ± SEM, n = 3. Curve fit results for each experiment are provided in the “Curve fit results” Supplementary file. NFU is normalized fluorescence units. Ligand parameters were compared statistically by paired two-tailed t-test, with the following p values: a0.258, b0.0496, c0.390, d0.0101.