TABLE II. Measurements of Intra-Aneurysmal Dimensions.

Implant (Fluoroscopy) 90 day (Histology) Avg. Neointima Thickness (mm)
Length (mm) Width (mm) Area (mm2) Length (mm) Width (mm) Area (mm2) % Decrease
Animal 1 Coil 8.8 9.3 61.5 7.43 7.30 37.13 39.62% 0.29
Animal 2 Coil 6.5 7.8 41.8 6.81 5.80 26.75 36.04% 0.27
Animal 1 Foam 6.1 8.4 39.2 2.55 3.22 6.89 82.42% 0.36
Animal 2 Foam 6.1 8.5 51.1 2.82 2.99 7.22 85.59% 0.43
Implant (Fluoroscopy) 180 Day (Histology) Avg. Neointima Thickness (mm)
Length (mm) Width (mm) Area (mm2) Length (mm) Width (mm) Area (mm2) % Decrease
Animal 3 Coil 5.7 6.6 32.9 4.07 6.18 20.09 38.88% 0.67
Animal 4 Coil 7.1 8.8 51.7 7.96 7.01 42.57 17.63% 0.56
Animal 3 Foam 6.6 8.1 38.5 1.54 2.47 2.59 93.26% 0.62
Animal 4 Foam 6.6 8.4 56.3 3.24 1.75 6.2 88.98% 0.40