Table 3.

Interobserver variance of inner vs. outer aortic measurements as described by Bland and Altman

Sinuses of Valsalva Sinotubular junction Ascending aorta Aortic arch Descending aorta
Outer-outer edge
 Mean difference (mm) − 0.93 0.50 − 0.60 0.40 0.30
 Limits of agreement (mm) − 8.9 to 7.1 − 7.5 to 8.5 − 11.4 to 10.2 − 3.0 to 3.8 − 3.7 to 3.3
 SD (mm) 4.1 4.1 5.5 1.8 1.8
 Variance (mm2) 16.9 16.8 30.1 3.1 3.1
 ICC (r) 0.75 0.67 0.48 0.83 0.88
Inner-inner edge
 Mean difference (mm) − 0.43 0.18 0.15 − 0.05 0.20
 Limits of agreement (mm) − 4.2 to 3.3 − 5.6 to 5.9 − 4.7 to 4.4 − 2.7 to 2.8 − 2.7 to 2.5
 SD (mm) 1.9 2.9 2.3 1.4 1.3
 Variance (mm2) 3.7 8.8 5.4 2.0 1.7
 ICC (r) 0.94 0.82 0.89 0.89 0.92
 P value (t test)  < 0.001  < 0.001  < 0.001  < 0.001  < 0.001
 P value (F test)  < 0.001  < 0.05  < 0.001 0.16 0.07

Intraclass correlation coefficient (ICC) values are given for outer and inner measurements. T-test was performed for comparison of mean differences and F-test for comparison of variances

Significant differences are in bold (significant at p < 0.05)