Skip to main content
. 2020 Jul 25;22:79. doi: 10.1186/s13058-020-01313-7

Table 2.

Results of the digitalMLPA BRCA1 classifier in the training and test sets

Predicted with digitalMLPA Class error rate (%)
BRCA1-like Non-BRCA1-like
Array-based score
Training set
  BRCA1-like 41 0 0
  Non-BRCA1-like 1 29 3
  Overall error rate 1
Test set
  BRCA1-like 39 3 7
  Non-BRCA1-like 3 25 10
  Overall error rate 9
Performance in the test set
  Sensitivity = 93%
  Specificity = 90%
  Accuracy = 91%