Skip to main content
. 2020 Jul 23;55(7):724–732. doi: 10.4085/1062-6050-134-19

Table 2.

Summary of Landing Error Scoring System Results

Item
Participants Displaying Error, No. (%)
Knee-flexion angle, IC 5 (11.63)
Hip-flexion angle, IC 3 (6.98)
Trunk-flexion angle, IC 8 (18.60)
Heel-to-toe landing 5 (11.63)
Asymmetric foot contact 4 (9.30)
Asymmetric foot contact timing 1 (2.33)
Asymmetric heel-toe/toe-heel landing 1 (2.33)
Lateral trunk-flexion angle, IC 7 (16.28)
Medial knee position, IC 5 (11.63)
Stance width: narrow 0 (0.00)
Stance width: wide 17 (39.53)
Foot internal rotation 2 (4.65)
Foot external rotation 8 (18.60)
Knee-flexion DSP 1 (2.33)
Hip-flexion DSP 4 (9.30)
Trunk-flexion DSP 15 (32.56)
Excessive trunk-flexion DSP 7 (16.28)
Maximum medial knee position 14 (32.56)
Asymmetric loading 13 (30.23)
Knee “wobble” 2 (4.65)
Sagittal-plane joint DSP 1 = 34 (79.07); 2 = 0 (0.00)
Overall impressiona 1 = 33 (76.74); 2 = 8 (18.60)

Abbreviations: DSP, joint angle displacement from initial ground contact to maximum joint angle during the descent phase of the jump landing; IC, initial ground contact.

a

Overall impression was the rater's subjective assessment of the participant's overall jump-landing movement quality.