Skip to main content
. Author manuscript; available in PMC: 2020 Jul 27.
Published in final edited form as: Phys Med Biol. 2019 Jul 5;64(13):135020. doi: 10.1088/1361-6560/ab205c

Table 2.

List of PQMs used as dosimetric OAR objectives in this study. PQMs were kept consistent between patients except when planning directives specified alternative PQMs (there were varying PQMs for larynx and cochlea). Note that not all OARs were present in all cases.

AR PQM Dose
Larynx DMean 30–45 Gy
Esophagus 35 Gy
Pharyngeal constrictors 54 Gy
Parotid (Rt. & Lt.) 26 Gy
Cochlea (Rt. & Lt.) 35–45 Gy
Oral cavity 40 Gy
Brainstem DMax 54 Gy
Optic nerves 54 Gy
Chiasm 54 Gy
Spinal cord 45 Gy
Eye (Rt. & Lt.) 54 Gy
Mandible 75 Gy
Brachial plexus 66 Gy