Table 2:
Levels of contaminants of concern in water, in Rosia Montana (RM) area, and Romanian regulatory exposure levels for metals in drinking water (μg/L) – maximum contaminant level (MCL) in drinking water.
| Pb | |||||||
|---|---|---|---|---|---|---|---|
| Water | Stream | ||||||
| 2005 | Upstream from RM mining area (n=3) | 1.5±0.9 | <1a | 4.8 | - | 1.8 | <1a |
| 2005 | Downstream from RM mining area (n=3) | 17±14.5 | 6±7.2 | 44.9±3.6 | - | 72.4±58.7 | <1a |
| 2006 | Upstream from RM mining area (n=3) | 2.7±3.5 | <1a | 2.2±1.3 | - | <1a | <1a |
| 2006 | Downstream from RM mining area (n=2) | 22.8±27.1 | 29.1±39.4 | 20.2±12.4 | - | 121±143.5 | 22.5 |
| 2007 | Upstream from RM mining area (n=2) | 2.1±0.3 | <1a | 3.5 | - | <1a | <1a |
| 2007 | Downstream from RM mining area (n=0) | - | - | - | - | - | - |
| 2008 | Upstream from RM mining area (n=1) | <0.05a | <1a | <1a | - | <1* | <1a |
| 2008 | Downstream from RM mining area (n=1) | 294 | 95.3 | 57.1 | - | 93.6 | 23.8 |
| Water | Drinking (n=10) | 5.4±3.1 | 2.1±0.3 | 4.2±1.5 | - | 5.4±3.1 | 1.7±1.9 |
| Romanian Regulatory Exposure Levels for metals (Drinking water) - MCL | 10 | 5 | 50 | 1 | 20 | 10 | |
Contaminants of concern concentrations (COCs) in μg/L for water (average ± SD).
Limit of detection (LOD). Bold value indicates Romanian regulatory exposure levels MCL.
“–” no data.