Table 1.
Provisional estimates of low tidal volume and computerized protocol use by site
| Sites | No. of ICUs | No. of ICU beds | No. of months CDS tool in place during the measurement period | Total no. of ventilated patient encounters during the measurement period | Estimated % encounters treated with initial set tidal volume ≤ 6.5 ml/kg PBW (%) | Estimated % encounters treated using at least one computerized protocol (%) |
|---|---|---|---|---|---|---|
| Site A* | 5 | 84 | 3 | 316 | 80 | 59 |
| Site B | 1 | 13 | 11 | 40 | 68 | 83 |
| Site C | 1 | 4 | 7 | 24 | 63 | 79 |
| Site D | 1 | 4 | 7 | 18 | 61 | 50 |
| Site E* | 1 | 16 | 5 | 65 | 60 | 91 |
| Site F | 1 | 6 | 5 | 0 | 60 | 0 |
| Site G* | 1 | 16 | 13 | 753 | 52 | 50 |
| Site H | 1 | 6 | 8 | 25 | 52 | 64 |
| Site I* | 1 | 24 | 11 | 648 | 38 | 10 |
| Site J | 1 | 8 | 9 | 23 | 30 | 13 |
| Site K | 1 | 4 | 11 | 15 | 27 | 40 |
| Site L* | 2 | 38 | 17 | 984 | 21 | 6 |
| Overall | 17 | 223 | 2911 | 42 | 28 | |
| Tertiary hospitals (%) | 59 | 80 | 95 | |||
| Tertiary hospitals only | 10 | 178 | 2766 | 41 | 27 | |
| Non-tertiary hospitals | 7 | 45 | 145 | 61 | 47 | |
| Absolute difference | 20** | 20** |
*Tertiary site
**Significant at < .001