Table 2.
Performances of Pain Intensity measurement compared to the PSPI manual detection (ground truth). CR = Classification Rate (%), PR = Precision (%), F1 = F1 measure (%).
| 5-folds cross validation | Leave one subject out validation | |||||
|---|---|---|---|---|---|---|
| Intensity | CR | PR | F1 | CR | PR | F1 |
| 0 | 97 | 95 | 96 | 61 | 65 | 57 |
| 1 | 96 | 97 | 92 | 72 | 37 | 67 |
| 2 | 96 | 97 | 91 | 79 | 35 | 40 |
| >=3 | 98 | 98 | 95 | 80 | 70 | 60 |