Table 1.
Estimated accuracy of Ribosolve modelsa
| System | No. nts | Final no. particles used for 3D reconstruction | Map resolution (Å) | Estimated accuracya (Å) |
|---|---|---|---|---|
| Tetrahymena ribozyme | 388 | 74,621 | 6.8 | 3.9 |
| hc16 product | 349 | 29,191 | 10. | 6.3 |
| hc16 | 338 | 21,263 | 11. | 6.2 |
| V. cholerae glycine riboswitch with glycine | 231 | 193,317 | 5.7 | 3.9 |
| V. cholerae glycine riboswitch apo | 231 | 230,891 | 4.8 | 3.3 |
| F. nucleatum glycine riboswitch with glycine | 171 | 35,578 | 7.4 | 3.4 |
| F. nucleatum glycine riboswitch apo | 171 | 20,269 | 10. | 3.5 |
| ATP-TTR-3 with AMP | 130 | 39,136 | 9.6 | 3.7 |
| ATP-TTR-3 apo | 130 | 71,045 | 10. | 3.7 |
| SAM-IV riboswitch with SAM | 119 | 225,303 | 4.8 | 3.6 |
| SAM-IV riboswitch apo | 119 | 260,244 | 4.7 | 3.7 |
Accuracy is estimated from the modeling convergence (accuracy = 0.61 × convergence + 2.4), where convergence is defined as the average pairwise RMSD of the top ten scoring models built into half map 1 vs. models built into half map 2 (see Methods).