Study characteristics |
Patient Sampling |
Serum BDG collected once or more often per patient as part of a prospective study |
Patient characteristics and setting |
95 adult ICU patients with sepsis and a stay of 5 or more days. Of these, 16 had proven IFI. The median age of patients was 69 years (range 18 to 93 years), and 68% were male |
Index tests |
Fungitell test using 80 pg/mL as cut‐off for positivity |
Target condition and reference standard(s) |
Mixed IFI determined by the 2008 EORTC criteria with BDG excluded |
Flow and timing |
Test within 24 to 72 hours of reference standard; all received index test and reference standard and were included in the analysis |
Comparative |
|
Notes |
|
Methodological quality |
Item |
Authors' judgement |
Risk of bias |
Applicability concerns |
DOMAIN 1: Patient Selection |
Was a consecutive or random sample of patients enrolled? |
Yes |
|
|
Was a case‐control design avoided? |
Yes |
|
|
Did the study avoid inappropriate exclusions? |
Yes |
|
|
Could the selection of patients have introduced bias? |
|
Low risk |
|
Are there concerns that the included patients and setting do not match the review question? |
|
|
Low concern |
DOMAIN 3: Reference Standard |
Is the reference standards likely to correctly classify the target condition? |
Yes |
|
|
Were the reference standard results interpreted without knowledge of the results of the index tests? |
Yes |
|
|
Could the reference standard, its conduct, or its interpretation have introduced bias? |
|
Low risk |
|
Are there concerns that the target condition as defined by the reference standard does not match the question? |
|
|
Low concern |
DOMAIN 4: Flow and Timing |
Was there an appropriate interval between index test and reference standard? |
Yes |
|
|
Did all patients receive the same reference standard? |
Yes |
|
|
Were all patients included in the analysis? |
Yes |
|
|
Could the patient flow have introduced bias? |
|
Low risk |
|