Skip to main content
. 2020 Jun 10;20(2):1285–1290. doi: 10.3892/etm.2020.8858

Table III.

Exercise tolerance and pulmonary function in both groups before and after treatment.

Groups Cases Treatment duration 6MWT (m) FVC (L) FEV1 (L)
Observation group 132 Before treatment 323.24±25.83 2.45±0.46 1.62±0.45
    After treatment 400.67±31.27a 3.84±0.57a 2.14±0.52a
    t value 21.93 21.80 8.688
    P-value <0.001 <0.001 <0.001
Control group 116 Before treatment 320.13±28.46 2.44±0.39 1.59±0.41
    After treatment 355.71±30.28 2.69±0.48 1.83±0.51
    t value 9.222 4.354 3.950
    P-value <0.001 <0.001 <0.001

aP<0.001 compared with the control group after treatment. 6MWT, 6-min walk test; FVC, forced vital capacity; FEV1, forced expiratory volume in 1 sec.