Skip to main content
. 2020 Jul 29;16:261. doi: 10.1186/s12917-020-02463-8

Table 4.

Comparison of FVEP measurements from two sessions

Session 1 Session 2
Parameter Mean SD Mean SD p-value CV CR ICC
P2 (ms) 55 5.2 56 5.5 0.65 3% 5 87%
N2 (ms) 142 8.3 139 7.9 0.55 4% 16 43%
P4 (ms) 234 20.4 227 28.8 0.66 6% 39 63%
N1P2 (μV) 6.8 2.9 5.4 3.8 0.52 30% 5.1 67%
P2N2 (μV) 9.7 4.4 7.8 4.8 0.49 24% 5.7 78%
N2P4 (μV) 8.6 4.2 7.7 4.0 0.69 27% 6.1 66%

Results from unilateral FVEPs from six horses at two separate recording sessions months apart. Mean ± SD for first and second sessions. A paired t-test was used to compare results from the two sessions, p-values< 0.05 were considered statistically significant. Coefficients of variation (CV), coefficients of repeatability (CR) and intraclass correlation coefficients (ICC) are reported