Skip to main content
. 2020 Jul 30;22(10):1294–1299. doi: 10.1016/j.jmoldx.2020.07.001

Table 1.

Comparison of Individual Sample Screening versus Mass Population Screening Approach in the United States for COVID-19

SARS-CoV-2 detection kit Screening approach Patients tested in one run/plate, N LOD, copies/mL Probability of number of samples positive in US population screening Additional reactions to be performed, N 940 Patients tested in following number of reactions Runs to screen 940 patients, N
PerkinElmer Inc. Individual sample screening 94 20 0.51 0 940 10
Mass population screening 940 200 5.16 20 118 2
US CDC Individual sample screening 30 5–10 0.033 0 940 32
Mass population screening 300 50–100 0.33 10 133 7

COVID-19, coronavirus disease 2019; LOD, limit of detection; SARS-CoV-2, severe acute respiratory syndrome coronavirus 2.