Table 1. Fit Parameters for Photolysis to eq 4aa.
| C1 | C2R0 | R2 | change in C1 | change in C2 | |
|---|---|---|---|---|---|
| retinol only: high | 0.156 ± 0.009 | –0.32 ± 0.01 | 0.9936 | N/A | N/A |
| retinol only: low | 0.149 ± 0.005 | –0.58 ± 0.04 | 0.9975 | N/A | N/A |
| retinol + StoppOx: high | 0.149 ± 0.004 | –0.74 ± 0.02 | 0.9981 | NS | P < 0.0005 |
| retinol + StoppOx: low | 0.098 ± 0.008 | –0.56 ± 0.08 | 0.9923 | P < 0.0005 | NS |
| retinol +BHT: high | 0.26 ± 0.01 | –0.74 ± 0.06 | 0.9941 | P < 0.0005 | P < 0.0005 |
| retinol +BHT: low | 0.211 ± 0.007 | –0.83 ± 0.02 | 0.9971 | P < 0.0005 | P < 0.0005 |
The errors indicate uncertainty in the fit parameters. The last two columns indicate the significance of the change in each parameter relative to retinol-only, as measured by the extra sum-of-squares F test. N/A = not applicable; NS = not significant.