Skip to main content
. Author manuscript; available in PMC: 2021 Sep 1.
Published in final edited form as: Ear Hear. 2020 Sep-Oct;41(5):1111–1124. doi: 10.1097/AUD.0000000000000831

Table 2.

Response rates for cervical and ocular VEMP to ACS and BCV stimuli.

CERVICAL VEMP OCULAR VEMP
GROUP ACS BCV ACS BCV
Ears with NH
(n = 10)
100% 100% 100% 100%
Ears with CI
(n = 27)
41% 67% 15% 52%*
Chi-Square
p-value
10.41
0.001
4.41
0.036
22.51
<0.001
7.42
0.006
*

Significantly higher response rates compared to ACS (p =.004)

ACS = air conducted stimuli, BCV = bone conducted vibration, NH = normal hearing, CI = cochlear implant