Table 3.
Parameters of the simulation experiments.
| Model runtime | 0–1000 days, with a warm-up phase of 500 days |
| Disruption | Loss of production capacity of producer P1 on day 500; Capacity available again after initial disruption time |
| Varying input parameters | Initial duration of disruption (P1) of 15–30 days |
| Degree of integration efficiency of BCT by variation of process time between 3–23 days for total completion of BCT-coordinated production service | |
| Output parameters | Transient response (network disruption costs, network recovery time, number of disrupted entities) |
| Number of runs | 67,200 with 336 iterations, each iteration with 200 replications |