Skip to main content
. 2020 Jul 11;7:100994. doi: 10.1016/j.mex.2020.100994

Table 1.

Quantitative Assessment of MRI Data at Each Enrollment Site.

Enrollment Site Cohort SNR CNR
MSSM + UW Inclusion Cohort (n = 87) 15.2 +/− 3.3 1.0 +/− 0.3
Exclusion Cohort (n = 9)* 8.3 +/− 2.6 0.9 +/− 0.2
P value <0.0001 0.65
MSSM Inclusion Cohort (n = 66) 15.1 +/− 2.9 1.0 +/− 0.4
Exclusion Cohort (n = 9)* 8.3 +/− 2.6 0.9 +/− 0.2
P value <0.0001 0.9
UW Inclusion Cohort (n = 21) 15.6 +/− 4.5 1.1 +/− 0.1
Exclusion Cohort (n = 0)
P value

For two subjects, the FreeSurfer processing pipeline could not be completed. Thus, only 9 of the 11 excluded patients could undergo signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) analysis. P values were determined using two-tailed T-tests. MSSM = Mount Sinai School of Medicine; UW = University of Washington.