Table 8.

Relationship between actual and predicted values for KI-26H and KI-AV2.

Name
KI-26H
KI-AV2
Settings (°C) Actual Value (°C) Predicted Value (°C) Error Actual Value (°C) Predicted Value (°C) Error
1st Zone 132 135.0287 -3.0287 129 129.4109 -0.4109
2nd Zone 153 153.0101 -0.0101 153 152.9500 0.05
3rd Zone 162 164.0193 -2.0193 160 159.6972 0.3028
4th Zone 160 160.0020 -0.002 159 158.8450 0.155
5th Zone 162 162.0000 0 161 162.4825 -1.4825
6th Zone 161 162.9937 -1.9937 160 160.1620 -0.162
7th Zone 160 160.0191 -0.0191 171 170.5228 0.4772
Clamp 171 170.9839 0.0161 155 154.6700 0.33
Neck 155 155.0033 -0.0033 170 168.4966 1.5034
Crosshead 170 167.9737 2.0263 169 170.2469 -1.2469
Die 175 173.9614 1.0386 175 173.3428 1.6572