Table 3.
Determination of cut-off, sensitivity and specificity values for KISS-1
| Cut-off | Optional abortion (n=24) | Abortus (n=27) | AUC (95% CI) | P-value |
|---|---|---|---|---|
| KISS-1 | ||||
| >2 | 20 (83.3)a) | 11 (40.7) | 0.713 (0.856–0.570) | 0.004 |
| <2 | 4 (16.7) | 16 (59.3)b) |
Values are presented as number (%). Data were analyzed using ROC (Honley & Mc Nell - Youden index J).
AUC, area under the ROC curve; CI, confidence interval; ROC, receiver operating curve.
Sensitivity;
Specificity.