Table 6.

Reported spherical equivalent outcomes and monocular visual acuities 3 months postoperatively following implantation of AT LISA tri 839MP lens in various studies

Author (year) Eyes SE LogMAR

UDVA CDVA UIVA CIVA UNVA CNVA
Pascual (2014)[27] 20 −0.28±0.55 0.09±0.16 0.01±0.11 0.30±0.11 0.22±0.11 0.18±0.11 0.11±0.13
Marques (2015)[25] 30 −0.02±0.39 0.08±0.12 0.04±0.10 0.14±0.09 - 0.22±0.07 -
Kretz (2016)[24] 100 −0.08 0.06 0.04 0.09 - 0.06 -
Bilbao-Calabuig (2017)[23] 4282 +0.26±0.47 0.04±0.08 0.02±0.06 0.00±0.17 - 0.07±0.10 -
Our study 46 −0.45±0.36 0.08±0.11 0.03±0.06 0.09±0.08 0.02±0.06 0.06±0.08 0.01±0.05

UDVA: Uncorrected distance visual acuity, CDVA: Corrected distance visual acuity, UIVA: Uncorrected intermediate visual acuity, UNVA: Uncorrected near visual acuity, CNVA: Corrected near visual acuity, SE: Spherical equivalent, CIVA: Corrected intermediate visual acuity, LogMAR: Log of the minimum angle of resolution