Skip to main content
. 2020 Feb 1;11(Suppl 4):S675–S680. doi: 10.1016/j.jcot.2020.01.015

Table 2.

Comparison of tested variables with prior screw and suture fixation studies.

Fixation
Method
Screw fixation Suture fixation Bioabsorbable screw fixation
Study Author Scrimshire et al.5 Senekovic et al.16 Kocher et al.17 Reynders et al.18 Huang et al.19 Vega et al.20 Zhao et al.21 Kogan et al.22 Osti et al.23 Jung et al.24 Honeycutt et al.
Lysholm Score 94 98.9 99.5 93.1 98 94 96.7 N/A N/A N/A 99.6
Negative Lachman N/A 26/28 (93%) 1/6 (17%) N/A 36/36 (100%) 7/7 (100%) 18/19 (95%) 4/6 (67%) 7/10 (70%) 16/16 (100%) 5/5
100%
Negative Pivot Shift N/A N/A 4/6 (67%) N/A 36/36 (100%) 7/7 (100%) N/A 6/6 (100%) N/A 16/16 (100%) 5/5
100%
Union Rate N/A N/A N/A 32/32 (100%) 36/36 (100%) N/A 19/19 (100%) N/A 10/10 (100%) 16/16 (100%) 5/5
100%