Skip to main content
. 2020 Jul 22;27:102357. doi: 10.1016/j.nicl.2020.102357

Table 2.

Intra- and inter-rater reproducibility assessed on the training dataset from ADNI (comprising 40 patients).

DSC Volume similarity Intraclass correlation Volume error rate False positive rate False negative rate
Intra-operator reproducibility 0.744
(0.723–0.766)
0.899
(0.875–0.922)
0.987
(0.971–0.994)
0.185
(0.145–0.226)
0.196
(0.164–0.228)
0.292
(0.259–0.325)
First segmentation first operator vs second operator 0.723
(0.699–0.747)
0.884
(0.856–0.914)
0.984
(0.962–0.992)
0.277
(0.199–0.355)
0.324
(0.286–0.362)
0.199
(0.168–0.231)
Second segmentation first operator vs second operator 0.701
(0.674–0.729)
0.844
(0.815–0.871)
0.974
(0.951–0.986)
0.310
(0.256–0.364)
0.262
(0.216–0.307)
0.290
(0.238–0.341)

DSC: Dice similarity coefficient. For each metric, the table displays the average and the 95% confidence interval within parentheses.