Data on the assay of chloroquine extemporaneous suspensions after filtration. The extemporaneous suspensions were obtained dispersing the crushed tablets in different aqueous vehicles (i.e., purified water, CMC, FOSP). An aqueous solution made of the pure drug substance was used as a control. The data are expressed as a mean percentage and relative standard deviation (RSD%) of three batches of suspension.

Vehicle Filter Drug assay (%)
RSD (%)
4 mg/ml 25 mg/ml 4 mg/ml 25 mg/ml
Control 101.1 100.7 1.8 10.9
0.2 µm, NYL 104.2 102.1 4.6 1.5
0.2 µm, PES 101.4 99.6 1.7 1.3
0.45 µm, PP 101.2 100.2 1.0 0.9
0.45 µm, PTFE 101.5 99.7 3.1 0.9
Water 101.3 106.9 2.4 10.0
0.2 µm, NYL 99.9 101.2 1.5 3.4
0.2 µm, PES 100.4 102.1 2.1 3.4
0.45 µm, PP 100.0 100.9 0.6 2.5
0.45 µm, PTFE 100.0 99.3 0.7 0.3
CMC 108.0 114.0 7.3 6.4
0.2 µm, NYL 102.4 103.7 0.9 1.0
0.2 µm, PES 104.3 100.4 1.7 2.5
0.45 µm, PP 104.4 105.5 1.7 3.7
0.45 µm, PTFE 103.4 102.6 1.6 3.9
FOSP 97.7 103.7 2.1 7.1
0.2 µm, NYL 105.4 103.3 2.4 5.8
0.2 µm, PES 100.4 97.9 2.9 2.7
0.45 µm, PP 99.7 99.0 3.9 2.2
0.45 µm, PTFE 99.4 102.3 2.7 3.1