Skip to main content
. 2020 Aug 1;1156:122297. doi: 10.1016/j.jchromb.2020.122297

Table 2.

Precision and accuracy for HPLC-MS/MS analysis of 6-O-demethylmenisporphine in rat plasma, liver, urine, bile and feces (n = 6).

Biosamples QC concentration (ng/mL) Intra-day Inter-day
Precision (RSD, %) Accuracy (RE, %) Precision (RSD, %) Accuracy (RE, %)
Plasma 5 8.2 −8.5 9.5 −5.6
15 6.2 −2.0 9.1 −2.6
150 7.1 −3.8 8.4 −9.1
1600 3.6 −2.8 10.1 −7.9
Liver 2 3.5 −5.4 7.2 −6.4
6 6.3 10.7 8.2 5.4
80 3.5 −10.2 5.4 −8.0
800 5.4 5.5 8.4 −10.9
Urine 2 7.9 −8.2 8.3 −1.5
6 10.0 7.7 9.8 8.9
80 6.7 −6.1 7.0 −5.0
800 5.4 −6.5 5.9 −7.0
Bile 2 9.0 −4.3 8.5 5.7
6 8.7 −1.9 11.0 4.1
80 5.4 −3.2 6.2 −7.0
800 6.8 5.4 7.6 11.2
Feces 2 7.6 8.9 9.7 −5.5
6 11.1 −10.9 9.0 −10.5
80 9.5 9.8 10.3 12.2
800 7.7 8.6 9.0 13.0