. 2020 Jul;8(14):878. doi: 10.21037/atm-20-4955

Table 3. CT acquisition parameters and scanner characteristics.

Study (No. reference) Image acquisition time CT scanner Slice thickness (mm) Slice interval (mm) Tube voltage (kv) Tube current modulation (mAs) Contrast enhancement No. CT readers CT reader experience (year)
Zhou SC et al. (14) Initial CT and follow-up CT the 16-MDCT LightSpeed scanner (GE Healthcare) or the uCT 760 scanner (United Imaging) 1.25 NR 100–120 200–300 No 2 13, 9 respectively
Wu J et al. (38) All patients’ initial CT and 35 last follow-up CT Siemens SOMATOM Definition AS 128-slice spiral CT, US; NeuViz 128-slice CT, China; GE LightSpeed V spiral CT, US 5 NR NR NR No 10 >5
Shi BB et al. (39) Unclear Cannon Aquilion Prime 160 16-slice CT 5 5 120 NR No 2 NR
Dai H et al. (8) On admission, within 24 h after admission GE Bright Speed Elite 16, Neusoft 16, SOMATOM Emotion, SOMATOM definition AS, PHLIPS MX-16, Philips 64-row spiral Ingenuity and the UNITED IMAGING Elite 16 5 NR 120 110 No 5 >10
Damiano C et al. (40) After the RT-PCR swabs 128-slice CT (GE Revolution EVO 64 Slice CT Scanner) 0.625 NR 120 100–250 No 2 15, 25 respectively
Han R et al. (11) On admission, initial CT BrightSpeed (GE Healthcare) or Somatom, Definition Flash (Siemens Healthineers) scanner 10 NR 120 50–350 No 2 >5
Zhao W et al. (9) On admission, mean interval between first CT scan and admission: 1d Anatom 16HD (Anke Medical Solutions), HiSpeed-Dual (GE Healthcare), 64-MDCT LightSpeed VCT (GE Healthcare), and Somatom Emotion (Siemens Healthcare) 0.625-5 NR 120 100–200 No 2 5, 15 respectively
Lu XF et al. (41) On admission, initial CT GE HealthOptima 680 and Brightspeed CT 0.625 5 120 200 No 2 NR
Zhu ZX et al. (42) On admission, initial CT GE Optima 660 0.625 5 120 50–400 No 2 NR
Cheng SP et al. (13) Initial CT: within 1w after positive RT-PCR test; follow-up CT: during hospitalization Siemens: 16-slice spiral CT; GE: 64-slice spiral CT; Philips: 128-slice spiral CT 5 5 100–120 100–200 No 2 NR
Li M et al. (43) Initial CT: on admission; follow-up CT: during hospitalization GE/Siemens: 64-slice spiral CT 2.5 NR 120 100 No 3 >10
Lei PG et al. (15) On admission, initial CT 128-slice MSCT (SOMATOM Definition AS+, Siemens, Germany); 16-slice MSCT (Aquilion16, Toshiba Medical, Nasu, Japan)” 1 or 5 NR 120 150 No 2 6, 20 respectively
Jie BK et al. (44) Initial CT: on admission; follow-up CT: during hospitalization 128-slice spiral CT system (LianYing, Shanghai, China) 5 NR 80–120 NR No 2 NR
Zhao SQ et al. (45) On admission, initial CT GE Optimal 680 64-channel 128-slice spiral CT 0.625 NR 120 120–150 No 2 NR
Pascal L. et al. (46) On admission, initial CT MDCT scanner with 64 channels 1 1 120 60–120 No 2 12, 32 respectively
Meng C et al. (47) Initial CT Neusoft 128-slice spiral CT 1 1 NR NR No 2 >5
Li XH et al. (48) On admission, initial CT Toshiba Aquilion 64-slice CT, GE Light Speed CT, GE Optima CT540 16-slice CT 5 2 120 120–200 No 2 NR
Li L et al. (49) 0–5 d from symptom onset Philips Brilliance iCT 256 5 NR 120 NR No 2 NR
Zhang Y et al. (50) Initial CT GE Lightspeed 16-slice CT 5 2 NR NR No NR NR
Xiao HJ et al. (51) Initial CT: on admission; follow-up CT: 3–6 d after first CT scan GE Revolution; SOMATOM Force, Siemens 1 0.5–1.0 120 50–200 No 2 >8
Hu R et al. (52) Unclear GE OPTIMA 540 16-slice CT scanner 5 5 120 200 No 3 NR
Bai HX et al. (53) Unclear SIEMENS: SOMATOM Definition; Emotion 16; SOMATOM go.Now; SOMATOM Definition AS20; SOMATOM Definition AS+ GE: BrightSpeed; LightSpeed Ultra; LightSpeed VCT/Resolution; Lightspeed 16/Optima CT580 Philips: Access CT; Hitachi ECLOS 0.6–2.5 NR 100–130 30–450 No 2 >5

CT, computed tomography; MDCT, multidetector computed tomography; MSCT, multislice computed tomography/multisection computed tomography; GE, General Electric Company; NR, not reported.