Recommended COVID-19 Nucleic Acid Detection Techniques

Organization conducted the study Test principle Sensitivity of test Manufacturer/commercially available devices Reference
Huazhong University of Science and Technology, Wuhan, China

Chest CT

RT-PCR

Chest CT 97%

RT-PCR 59%

- (11)
Fred Hutchinson Cancer Research Center, WA, USA Real-time RT-PCR 84.6%

Xpert® Xpress by Cepheid

Roche Molecular System

(12)
University of California, San Francisco, USA CRISPR Not reported

Cepheid Sherlock Biosciences

Mammoth Biosciences

(13)
Wuhan Institute of Virology, China Isothermal nucleic acid amplification technology 95% Abbott® ID Now (7,14,15)