Table 2. Relationship between needle insertion angle along linear path and the actual puncture path.

Needle insertion angle along linear path The actual puncture path (%) P value
Non-linear Linear path
80°–90° (n=43) 3 (7.0) 40 (93.0) <0.01
70°–80° (n=49) 39 (79.6) 10 (20.4)