Skip to main content
. 2020 Jul;12(7):3539–3548. doi: 10.21037/jtd-20-677

Table S5. Predictors of changes in frequency of bronchoscopy after stent removal. Y = Δbronch/month (after − pre), n=21.

Predictors Univariate Multivariate Reduced
Estimate Standard error t-value P value Estimate Standard error t-value P value Estimate Standard error t-value P value
Age at transplant −0.01 0.01 −0.66 0.514
Gender 0.27 0.24 1.16 0.259
Baseline FEV1 −0.3 0.16 −1.91 0.073 −0.38 0.2 −1.88 0.083
Location of stent 0.891
   LMSB 0.23 0.34 0.69 0.498
   RMSB 0.09 0.39 0.22 0.827
   RBI 0.01 0.64 0.01 0.989
   Peripheral REF
Type of stent 0.981
   CSEMS −0.07 0.37 −0.18 0.861
   USEMS 0.01 0.28 0.04 0.97
   Silicone REF
Type of airway complication
   Dehiscence 0.01 0.31 0.05 0.963
   Cicatrix scar −0.11 0.24 −0.47 0.645
   Pseudomembrane −0.33 0.26 −1.3 0.208
   Malacia 0.08 0.26 0.31 0.756
Days prior to stent placement 0 0 0.97 0.344
# of days with stent 0 0 −1.53 0.143 0 0 −1.06 0.31
Stent related complications
   Mucous plugging −0.21 0.24 −0.87 0.393
   Migration 0.21 0.28 0.75 0.462
   Bleeding −0.05 0.41 −0.13 0.9
   Granulation tissue −0.34 0.23 −1.45 0.164 0.02 0.25 0.09 0.931
   Fracture
   Restenosis −0.43 0.25 −1.74 0.098 0 0.28 0 0.997
   Dehiscence −0.26 0.41 −0.64 0.532
Symptomatic improvement after stent −0.15 0.57 −0.27 0.794
# of stent exchanges −0.19 0.08 −2.34 0.03 −0.08 0.09 −0.85 0.409 −0.19 0.08 −2.34 0.03

FEV1, forced expiratory volume over 1 second; LMSB, left mainstem bronchus; RMSB, right mainstem bronchus; RBI, right bronchus intermedius; CSEMS, covered self expanding metallic stent; USEMS, uncovered self expanding metallic stent.