Skip to main content
. 2020 Jun 29;9(7):523. doi: 10.3390/pathogens9070523

Table 4.

Number of Legionella spp. colonies (CFU/L) appearing on different plates: BCYEα positive results vs. MWY negative results.

Oxoid Xebios
Samples BCYEα MWY L. spp. B. Flora
on
BCYEα
B. Flora
on
MWY
Samples BCYEα MWY L. spp. B. Flora on
BCYEα
B. Flora on
MWY
1 50 0 Lp3 1+ 0 1 50 0 Lp3 0 /
2 50 0 Lp1 1+ 0 2 500 0 Lp1 1+ /
3 150 0 Lp6 1+ 0
4 200 0 L.spp 0 0
5 400 0 L.spp 0 0
6 600 0 L.spp 1+ 0
7 1050 0 L.spp 0 0
8 2200 0 L.spp 2+ 0
9 2350 0 L.spp 0 0
10 3400 0 L.spp 0 0

Background (B.) flora was measured by semiquantitative counting: four categories were determined according to the visual density of colonies spread onto the plate, where zero is no background flora and 3+ is massive contamination (see supplementary materials). Lp 1 = L. pneumophila serogroups 1; Lp 3 = L. pneumophila serogroups 3; Lp 6 = L. pneumophila serogroups 6; L.spp. = Legionella spp. non-pneumophila.