Skip to main content
. 2020 Jul 13;12(7):1543. doi: 10.3390/polym12071543

Table 3.

TGA-FTIR gas/volatile absorption intensities (A) collected under air and N2, normalised to respective pure PA66 values (A = 1.00). The compositions of these samples correspond to those in Table 1 and Table 2. Those samples marked with an asterix (*) have the best fire performance.

Sample CO2
(Air)
CO2
(N2)
NH3
(Air)
NH3
(N2)
CHx
(Air)
CHx
(N2)
Control 1.00 1.00 1.00 1.00 1.00 1.00
BrPS 0.76 0.33 1.27 1.01 1.24 1.24
BrPBz 0.77 0.63 0.97 1.58 1.43 2.54
ZnW 1.06 0.92 1.16 1.24 1.11 1.34
SnW 1.04 1.30 1.55 2.03 1.26 1.87
SnW-BrPS 1.06 1.05 1.21 2.24 1.34 1.50
SnW-BrPBz 1.09 0.73 2.01 2.37 1.51 1.59
ZnW-BrPS * 1.06 0.92 1.28 1.75 1.32 0.55
ZnW-BrPBz * 1.91 0.50 1.73 1.28 0.77 0.28