Skip to main content
. 2020 Jul 10;9(7):2184. doi: 10.3390/jcm9072184

Table 3.

Summary of the basic parameters and common quality measures of the models.

AUC (CI) Cut-Off Point Specificity Sensitivity Accuracy TP/TN/FP/FN Intercept (a0) Coefficients
x1 = miR-298 95.70% 1.5 100% 91.30% 0.95 17/2/0/21 –649.78 a1 = 31.25
x2 = miR-1307-3p a2 = 27.99
x3 = miR-491-5p a3 = 81.50
x1 = miR-298 82.50% 1.5 82.35% 82.60% 0.83 14/4/3/19 −5.99 a1 = 0.64
x2 = miR-1307-3p a2 = 0.70
x1 = miR-298 92.70% 1.5 94.20% 91.30% 0.93 16/2/1/21 −16.81 a1 = 1.32
x2 = miR-491-5p a2 = 2.53
x1 = miR-1307-3p 87.60% 1.5 88.23% 86.96% 0.86 15/3/2/20 −23.09 a1 = 1.63
x2 = miR-491-5p a2 = 3.06

AUC, area under the curve (AUC) of the receiver operating characteristic (ROC) curves; CI, confidence interval; FN, false negative; FP, false positive; TN, true negative; TP, true positive.