Optimal threshold, sensitivity, specificity, overall accuracy, and ROC area imaging variables that were significant with univariate analysis

Variable Threshold Specificity Sensitivity Overall Accuracy ROC Area
Base infarct volume (mL) 24.1 76.5% 63.6% 70.1% 0.717
Final infarct volume (mL) 45 82.4% 59.1% 70.7% 0.706
Volume of ATD>6 s (mL) 27.77 88.2% 63.6% 75.9% 0.777
Volume of ATD2–6 s (mL) 38.28 82.4% 81.8% 82.1% 0.906
rCBF 1 58.8% 90.9% 74.9% 0.709
rCBV2–6 s 1.6 88.2% 81.8% 85.0% 0.900
PCIa 61.70 88.2% 100.0% 94.1% 0.973
a

PCI = Volume of ATD2–6 seconds × rCBV2–6 seconds.