Table 1:
Clinical NST for trigeminal neuropathya
| Level A: Spatiotemporal Sensory Perception | Level B: Contact Detection with Monofilament | Level C: Pain Threshold and Tolerance | |
|---|---|---|---|
| Heat Temperature Threshold <47 | |||
| Heat Temperature Tolerance <50 | |||
| Direction Sensitivity <90% | Pressure Pain Threshold <1.5 lb. | ||
| Static 2-Point Discrimination <18 mm | <2.83 | Pressure Pain Tolerance <2.0 lb. | |
| Normal | Present | Present | Present |
| Mild | Failed | Present | Present |
| Moderate | Failed | Failed | Present |
| Severe | Failed | Failed | Elevated |
| Complete | Failed | Failed | Absent |
Present: values recorded at test and control sites exhibit comparable sensitivity within published normative range. Failed: values recorded at test site sensitivity are less than that of control sites or published normative range. Elevated: values recorded at test site sensitivity are greater than that of control sites or published normative range but below maximum of test device (ie, 6 lbs.). Absent: values recorded at test site sensitivity are greater that maximum of test device (ie, 6 lbs.).