Skip to main content
. 2018 Dec 28;5(1):166. doi: 10.18063/ijb.v5i1.166

Figure 6.

Figure 6

(A) Growth rate σ versus the wavenumber k for a jet with b (distance between two radial electrodes) >>1, χ = 0.6, C (Ohnesorge number) = 1, and β (liquid relative permittivity) = 2 and several values of the relaxation parameter α; (B) Growth rate σ versus the wavenumber k for a jet with different values of the Ohnesorge number C (b >>1, α=1, β=1, χ=0.6). (C) Growth rate σ versus the wave number k for a jet with b>>1 and b=2. The other parameters are fixed at C=1, α=1, and β=2. Several values of the electrification number χ are plotted[81]. Adapted by permission from Jose Lopez-Herrera et al. (2005) under the AIP Publishing LLC.