Skip to main content
. 2020 Aug 11;9(2):299–306. doi: 10.1016/j.jvsv.2020.08.005

Table III.

Comparison of demographics, serum d-dimer, rates of deep vein thrombosis (DVT), pulmonary embolism (PE), and scan times with conventional versus COVID-19-specific ultrasound (US) protocol

Variable DVT US conventional protocol (n = 53) COVID-19-specific protocol (n = 44) P value
Age, years 55 ± 17 58 ± 16 .31
Male sex 23 (43.3) 25 (56.8) .22
d-Dimer, ng/mL 1704 (1119-6457) 2636 (1306-5186) .51
DVT 14 (24.5) 5 (15.9) .08
PE 6 (11.3) 4 (9.1) 1.00
Scan time, minutes 13 (9-15) 6 (5-8) <.0001

Values are mean ± standard deviation, median (interquartile range), or number (%).

Boldface entries indicate statistical significance.