Skip to main content
. 2020 Jul 28;9(8):39. doi: 10.1167/tvst.9.8.39

Table 2.

Age Dependence of Refractive Error and In Vivo Ocular Biometry

Regression Equation R 2 P
Mean sphere subjective refraction (D)* –2.228 + 0.029 × age 0.095 0.021
Corneal central thickness (mm) 0.547 – 0.001 × age 0.004 0.648
Corneal curvature (mm) 7.975 – 0.003 × age 0.048 0.104
Axial length (mm)
 Uncorrected* 24.681 – 0.012 × age 0.070 0.028
 After correction 24.012 – 0.004 × age 0.012 0.420
Lens thickness (mm)
 MRI* 3.237 + 0.018 × age 0.571 <0.001
 Lenstar* 3.237 + 0.018 × age 0.643 <0.001
Lens radius of curvature (mm)
 Anterior* 13.430 – 0.072 × age 0.525 <0.001
 Posterior* –5.481 + 0.013 × age 0.199 <0.001
Anterior chamber depth (mm)* 3.403 – 0.011 × age 0.482 <0.001
*

The results of the regression analysis were statistically significant.