Skip to main content
. 2020 Aug 12;25(8):085001. doi: 10.1117/1.JBO.25.8.085001

Fig. 1.

Fig. 1

Diagram of laser delivery to sample and method of verifying beam uniformity. (a) Diagram of laser combiner and exposure incubator (EI) used in the PBM experiments. Laser outputs are passed into the mirror assembly (MA) at the bottom-left of the diagram, with shutters (Sh) placed to allow for selection of individual or combinations of wavelengths. Final output to the FO, continues into the EI. Within the incubator, an image of the fiber tip was projected on to a black floorplate to create a 15-cm flat-top laser profile. (b) Diagram depicting method used to verify uniformity of laser irradiance.