Skip to main content
. 2019 Jun 29;19(4):1331–1346. doi: 10.1007/s10237-019-01195-5

Table 1.

Parametric FEA input variable name and bounds for the seven variables in the parametric FE model

Input variable name Lower bound Upper bound
PC 1 (residuum length), v1 − 1 σ (short) + 1 σ (long)
PC 2 (residuum profile), v2 − 1 σ (bulbous) + 1 σ (conical)
Bone length, v3 − 15% + 30%
Soft tissue stiffness (E, kPa), v4 35 55
Proximal press fit, v5 − 2% + 6%
Mid press fit, v6 − 2% + 6%
Distal press fit, v7 − 2% + 6%