Skip to main content
. 2020 Aug 12;10:13606. doi: 10.1038/s41598-020-70604-y

Table 2.

Results of simulation study to determine the optimal bandwidth based on the signal size.

Signal Size MTPs Bandwidth pValue.thresh True positive TPRate False positive FPRate
Small BH 5 0.034 101 0.902 35 0.000
Small WY 5 0.050 101 0.902 35 0.000
Medium BH 10 3 × 10–4 1411 0.953 235 0.001
Medium WY 10 1 × 10–3 1442 0.974 411 0.001
Large BH 15 0.001 13,219 0.900 65,291 0.173
Large WY 15 0.279 13,234 0.901 65,762 0.174
Large BH 19 7.78 × 10–7 13,419 0.914 45,718 0.121
Large WY 19 1 × 10–5 13,584 0.925 51,627 0.137

MTP, multiple comparison procedure; pValue.thresh, p value considered significant change for a voxel; True Positive, number of true positives detected; TPRate, true positive rate; False Positive, the number of false positives detected; and FPRate, the false positive rate.