Skip to main content
. 2020 Aug 12;11:353. doi: 10.1186/s13287-020-01870-w

Table 2.

Change of the functional parameters of the retina according to study timepoints

Patient No. Eye BCVA FPDI ERG amplitudes ERG implicit times
T0 T1 T2 T0 T1 T2 T0 T1 T2 T0 T1 T2
1 R 100 110 110 5 11 12 3.2 6.3 6.4 43.8 38.8 38.7
2 L 80 87 90 6 16 19 2.1 2.3 2.6 42.7 42.7 40.8
3 R 80 88 88 10 12 12 1.5 3.0 2.9 42.3 40.7 40.4
4 L 84 88 91 6 10 11 1.9 4.1 4.0 40.3 40.0 39.9
5 L 50 74 50 4 7 5 2.4 11.1 2.6 47.4 42.5 46.3
6 L 80 85 85 7 13 14 3.6 19.7 19.9 50.0 50.0 49.8
7 R 50 56 60 15 22 23 1.6 2.7 2.8 50.0 50.0 49.8
8 L 80 87 87 5 7 7 1.4 2.4 2.3 50.0 46.1 45.8
9 L 72 79 79 8 14 14 2.0 2.5 2.6 44.6 42.1 42.0
10 L 50 55 55 14 19 18 4.4 6.0 5.8 38.5 34.9 35.0
11 R 65 77 77 5 10 9 1.0 4.1 3.8 44.1 35.7 36.0
12 R 65 74 74 4 8 8 11.0 16.9 16.3 26.9 26.7 26.8
13 L 65 87 87 5 9 10 1.4 7.4 7.6 43.4 22.8 22.4
14 R 50 69 70 14 26 26 2.8 3.9 4.0 38.6 34.0 39.9
15 L 89 110 110 4 16 16 2.0 2.7 2.8 38.1 38.0 37.8
16 R 80 83 77 5 5 4 0.9 1.3 0.9 49.1 34.1 42.9
17 L 50 59 60 6 6 7 1.7 4.0 4.0 32.8 23.5 24.0
18 L 80 85 85 10 12 12 1.5 8.9 8.8 34.8 22.5 23.5
19 R 50 65 65 14 15 15 1.3 4.9 4.9 40.8 32.1 32.7
20 R 60 77 77 10 12 13 1.6 1.8 2.0 49.2 49.2 49.0
21 R 50 59 60 4 5 5 1.5 1.8 1.8 44.0 44.0 43.8
22 L 77 87 87 8 10 11 2.6 3.0 3.0 46.0 43.5 43.8
23 R 70 70 70 10 10 10 5.0 5.1 5.0 48.2 48.2 48.0
24 L 98 110 110 7 10 11 1.5 2.7 2.7 39.6 24.4 24.2
25 L 85 91 91 10 16 18 1.4 1.9 2.1 35.7 29.0 29.0
26 L 89 110 110 7 10 10 5.0 8.9 8.7 41.6 35.2 35.2
27 R 85 94 94 10 12 12 2.0 2.8 2.9 48.2 46.8 46.0
28 R 50 55 50 4 4 4 1.8 9.6 3.6 46.0 34.0 39.0
29 R 50 50 50 5 5 5 2.8 6.6 4.8 39.5 39.5 39.3
30 L 89 94 94 6 8 8 0.7 2.9 2.8 48.8 36.6 37.0
31 R 74 85 85 15 16 16 1.6 3.3 3.2 48.2 44.1 44.0
L 80 87 87 14 15 15 2.0 2.8 2.8 47.4 43.2 43.2
32 R 60 77 77 8 11 11 1.9 2.0 2.0 44.0 36.0 37.0
L 60 77 77 7 10 10 1.5 1.7 1.7 47.0 38.0 39.0

BCVA best corrected visual acuity (ETDRS letters), FPDI fundus perimetry deviation index (%), ERG amplitudes full-field flicker electroretinography amplitudes (mV), ERG implicit times full-field flicker electroretinography implicit times (ms), T0 (baseline) just before the Wharton jelly-derived mesenchymal stem cell injection, T1 6th month after injection, T2 12th month after injection