. 2020 May 30;9(12):e012405. doi: 10.1161/JAHA.119.012405

Table 4.

Sensitivity Analysis With ICD Defined as ICD Implanted During Index Hospitalization

Patients With Diabetes Mellitus
Raw Mortality Rate (%) Cumulative Incidence Rate (%) Unadjusted Hazard Ratio (95% CI) Adjusted Hazard Ratio (95% CI)
ICD No ICD ICD No ICD
54.4 59.3 62.5 75.6 HR, 0.65 (0.56–0.76); P<0.0001 HR, 0.64 (0.55–0.74); P<0.0001
Patients Without Diabetes Mellitus
Raw Mortality Rate (%) Cumulative Incidence Rate (%) Unadjusted Hazard Ratio (95% CI) Adjusted Hazard Ratio (95% CI)
ICD No ICD ICD No ICD
43.8 58 51.2 70.5 HR, 0.53 (0.47–0.60); P<0.0001 HR, 0.56 (0.49–0.64); P<0.0001

P=0.11 for adjusted interaction P value between diabetes mellitus and ICD implantation for all‐cause mortality. ICD indicates implantable cardioverter‐defibrillator; HR, hazard ratio.