Skip to main content
. 2019 Apr 26;9(3):167–174. doi: 10.4103/eus.eus_4_19

Table 1.

Characteristics of included randomized controlled trials

Study Arm Sample size Study period/design Country Age Gender male Lesion size (cm) Location head/uncinate Stylet use Suction ROSE Needle
Alatawi et al., 2015[18] FNB FNA 50 50 2012-2013/parallel France 67.8±13.1 68±11.2 28 (56%) 35 (70%) 3.2±0.5 3.3±0.2 34 (68%) 38 (76%) No Yes No ProCore® Echo Ultra®
Bang et al., 2012[19] FNB FNA 28 28 2011/parallel USA 65±15.4 65.4±11.1 15 (53.6%) 16 (57.1%) 3.2±0.9 3.3±0.7 20 (71.4%) 20 (71.4%) No Only in FNB group Yes ProCore® Expect®
Bang et al., 2018[20] FNB FNA 4646 Cross-over USA 67.9±14.7 28 (60.9%) 2.9±0.8 28 (60.9%) NR No Yes Acquire® Expect®
Cheng et al., 2018[21]* FNB FNA 123 126 2014-2016/parallel China 58.3±11.1 58.3±12.2 59.3% 63.6% 2.91 2.95 NR Only at first two passes Only at 3 and 4 passes No ProCore® EchoTip®
Ganc et al., 2014[22]a FNB FNA 30 30 Cross-over Brazil NR NR NR NR NR NR No ProCore® EchoTip®
Hucl et al., 2013[23]* FNB FNA 69 69 2011-2012/cross-over India 51.7±13.6 37 (53.6%) 4.19±1.7 54% No Yes No ProCore® EchoTip®
Lee et al., 2017[24]* FNB FNA 9 7 2013-2014/parallel Korea 69 (26-85) 66 (36-81) 62% 75.8% 4.4±3.2 3.7±2 NR Yes Partially No ProCore® EchoTip®
Noh et al., 2018[25] FNB FNA 60 60 2013-2015/cross-over Korea 61.6±10 35 (58.3%) 3.1±0.8 23 (38.4%) No No Yes No ProCore® EZShot 2®
Othman et al., 2017[26] FNB FNA 29 60 2013-2014/parallel USA 67.9±10.3 63.4±10 16 (55.1%) 27 (45%) NR 16 (55.1%) 30 (50%) No Yes Yes ProCore® EZShot 2®/Expect®
Sterlacci et al., 2016[27]* FNB FNA 38 38 2011-2013/cross-over Germany 68±12 51.8% 3.3±1.2 NR No Yes No ProCore® EchoTip®
Vanbiervliet et al., 2014[28] FNB FNA 80 80 2012/cross-over France 67.1±11.1 49 (61.2%) 3.3±1 50 (62.5%) No Yes No ProCore® EchoTip®

*Trials including either pancreatic and extra-pancreatic masses. Only pancreatic lesions were reported in the table and included in the analysis, aConference abstract, bThree-arm trial comparing two different FNA needles and FNB. Data from the two FNA arms were merged. FNB: Fine-Needle Biopsy; ROSE: Rapid on-site evaluation; NR: Not reported