Table 2.
Range Lx, settling time ts and settling radius Rs of droplet with initial radius R0 = 60 μm and 100 μm at different RH.
|
R0 = 60 μm | ||||||||
|---|---|---|---|---|---|---|---|---|
| RH | ts (s) | Lx (m) | Rs (μm) | Percentage Decrease in R | ||||
| 0% | – | – | – | – | ||||
| 50% | 7.87 s | 0.75 m | 49.35 μm | 17.75% | ||||
| 90% |
7.94 s |
0.80 m |
58.25 μm |
2.92% |
||||
| R0 = 100 μm | ||||||||
| RH |
ts (s) |
Lx (m) |
Rs (μm) |
Percentage Decrease in R |
||||
| 0% | 4.01 s | 0.98 m | 92.46 μm | 7.54% | ||||
| 50% | 4.02 s | 1.07 m | 96.98 μm | 3.02% | ||||
| 90% | 4.06 s | 1.20 m | 99.47 μm | 0.53% | ||||