Skip to main content
. 2020 Aug 18;183:107196. doi: 10.1016/j.buildenv.2020.107196

Table 4.

Fate of the smaller droplets with initial radius R0 in the range 20 μm–50 μm in an environment with air temperature Tf= 18 °C and RH = 50%.

R0 (μm) 20 30 40 50
ta (s) 1.33 3.02 5.38 8.43
xa (m) 0.18 0.30 0.35 0.58
ya (m) 0.06 0.28 0.74 1.74

ta and (xa, ya): time and position at which droplet becomes an aerosol droplet (R ≤ 2.5 μm).